Magnat MTT 990 Unboxing & Commissioning
Arrival: Turntable MTT 990 has arrived.
Opening: Carefully open the packaging.
Unpacking: Remove the operating instructions and the cover from the packaging.
Unpacking: Remove everything else from the packaging.
Unpacking: Remove adhesive tapes from Styrofoam parts. Remove the platter first, then remove the turntable.
Setting up the turntable
Mounting the platter: Carefully place the platter onto the motor axis (do not tilt)
Removing transportation locks: Remove the transportation locks from the tonearm
Mounting the counterweight: Screw the counterweight onto the tonearm
Mounting the pick-up system: Screw the cartridge onto the tonearm
Horizontal alignment and feet adjustment: Align the turntable via app or bubble level.
Horizontal alignment and feet adjustment: By turning the feet.
Balancing the tonearm: Remove needle cover and balance the tonearm.
Setting scale to zero: Set adjustment scale to zero.
Adjusting stylus force/antiscating: Set the stylus force and the antiscating to the same value.
Mounting the cover: Slide the hinges into the slots of the cover.
Mounting the cover: Slide the hinges into the recesses and fix the cover to the turntable.
Connection to amplifier: Connect cinch cable and ground cable to the MTT 990 as well as to the MM input of the amplifier.
Connection to power supply: Connect the MTT 990 to the power supply.
Switching on: Operate ON/OFF switch of the MTT 990.
Switching on amplifier: Select MM input on the amplifier (for original or MM systems).
Turning on motor: Select speed, eg. 33 1/3.
Enjoying your MTT 990: Unlock the tonearm, lift tonearm, move it towards the vinyl and lower it.
MTT 990: Setting up a pick-up system for the version without cartridge or upgrades
(Observe the operating instructions of the MTT 990 and of the cartridge supplier!)
Mounting cartridge onto the headshell: Observe assembly instructions of the cartridge supplier!
Adjusting the tonearm height: Goal: Align the tonearm parallel to the platter.
Unlocking the tonearm base: Goal: Align the tonearm parallel to the platter.
Height adjustment of the tonearm base: Goal: Align the tonearm parallel to the platter.
Checking the tonearm alignment: Align the tonearm parallel to the platter (with tonearm lowered).
Locking the tonearm base: Goal: Align the tonearm parallel to the platter.
Adjusting the pick-up system: We recommend using a Schön template for the adjustment.
Height adjustment of tonearm lift: Goal: 8-12 mm distance between needle and platter with tonearm lift raised.
0 Comments